Your Trusted Dosimeter Calibration Provider

Micro Precision is a trusted dosimeter calibration provider because its laboratories hold ISO/IEC 17025:2017 accreditation and issue NIST-traceable certificates of calibration for every radiation instrument serviced. Micro Precision’s ISO/IEC 17025:2017 accredited laboratories issue NIST-traceable certificates of calibration for dosimeters used across medical, industrial, defense, and research settings, supported by a global network of more than 50 calibration laboratories.

Our metrologists work with a variety of radiation dosimetry instruments, including electronic personal dosimeters, direct-reading dosimeters, and universal dosemeter and electrometer systems from manufacturers such as Dosimeter Corp (DCA), PTW Freiburg, and Fluke Biomedical / RaySafe. Compliance officers rely on our documented traceability records for regulatory review, while quality managers benefit from a single accredited vendor supporting their entire radiation instrument fleet.

Fill out our Dosimeter calibration service request form

Why Dosimeter Calibration Matters

Dosimeter calibration matters because inaccurate radiation dose readings create safety risks for personnel and compliance gaps for the facilities responsible for monitoring them. An uncalibrated dosimeter can under-report or over-report exposure without any visible indication, which is why documented, standards-based calibration is a regulatory requirement rather than a best practice.

Calibration practices connect directly to ANSI N13.5, NRC Regulatory Guide 8.4, and ANSI/NCSL Z540.3 requirements for radiation protection instruments. Compliance officers need a defensible audit trail linking every dose reading back to a NIST-traceable reference source, and quality managers need documentation that satisfies ISO/IEC 17025:2017 and facility radiation safety programs. Procurement teams benefit from working with a single accredited vendor rather than managing multiple uncertified calibration sources.

Ensure Accurate Dosimeter Calibration

Ensuring accurate dosimeter calibration services means following a documented process from intake through return. Micro Precision receives each dosimeter, inspects it for physical damage, exposes it to a known NIST-traceable radiation dose from a calibrated source, adjusts or documents any deviation, and issues a full certificate of calibration before returning the instrument.

Every calibration is performed under controlled laboratory conditions by trained metrologists, with results recorded for full traceability. Micro Precision offers standard turnaround as well as faster service options for dosimeters needed back in service quickly, without compromising the accuracy of the calibration process.


Our Calibration Options

Micro Precision offers both in-lab and on-site dosimeter calibration options to match your facility’s radiation safety program. In-lab calibration ships your dosimeter to one of our ISO/IEC 17025:2017 accredited laboratories for calibration under fully controlled reference-source conditions. On-site calibration sends a qualified technician to your facility, minimizing downtime for radiation instruments that are difficult to remove from active monitoring programs.

Faster turnaround options are available for time-sensitive calibration needs, in addition to our standard service timeline. Whether calibrating a single dosimeter or an entire fleet of radiation monitoring instruments, Micro Precision structures the service around your facility’s compliance schedule.

Dosimeters We Calibrate

Micro Precision calibrates a variety of radiation dosimetry instrument types, including instruments from leading manufacturers.

  • Electronic personal dosimeters (EPDs)
  • Direct-reading dosimeters (DRDs)
  • Thermoluminescent dosimeters (TLDs)
  • Ionization chamber survey meters
  • Universal dosemeter / electrometer systems
  • Radiation area monitors
  • X-ray and diagnostic radiation dosimeters
  • Dosimeter readout and calibration systems

Micro Precision calibrates instruments from manufacturers including Dosimeter Corp (DCA), PTW Freiburg, and Fluke Biomedical / RaySafe. If your specific dosimeter model is not listed, it is likely supported. Contact Micro Precision to confirm calibration availability for your instrument.

Looking for noise dosimeter calibration instead? See our sound level meter and noise dosimeter calibration services.

Calibration Service Levels Offered

Micro Precision offers three dosimeter calibration service levels so compliance officers and quality managers can match documentation depth to program requirements.

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Dosimeter Calibration Services

Micro Precision delivers ISO/IEC 17025:2017 accredited, NIST-traceable dosimeter calibration services for electronic, direct-reading, and survey meter radiation instruments across a global network of more than 50 calibration laboratories. Compliance officers, quality managers, and radiation safety teams rely on Micro Precision for documented traceability, in-lab and on-site service options, and a single accredited vendor for their entire dosimeter fleet. Request a calibration quote to get started.

Please complete our quick Dosimeter calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
3M Quest Edge 4 Personal Noise Dosimeter3MEdge 4
Aloka ANY Digital DosimetersAloka
Ametek - Dupont MK-1 Audio DosimeterDupontMK-1
Ametek - Dupont MK-2 Audio DosimeterDupontMK.2
Ametek - Dupont MK-3 Audio DosimeterDupontMK-3
Any Dosimeter 1 Point 20R - Direct ReadingAnyDosimeter 1 Point 20R
Any Dosimeter Digital not listed elsewhere - Direct ReadingAnyDosimeter Digital not listed elsewhere
Any Dosimeter Each Additional Point (anything more than 1 Point)AnyDosimeter Each additional point
Arrow-Tech GSD-3054 DosimeterArrow-TechGSD-3054
Arrow-Tech W138 Direct-Reading Dosimeter / Mobile Radiation Detection / Radiation Dosimeter - Arrow 138Arrow-TechW138
Casella CAL-320 / CAL-6681 Dosimeter with MicrophoneCasella
Cirrus CR110A Sound DosimeterCirrusCR110A
Cure UV 302084-A Cure Check UV Dosimeter for UV MeasurementCure UV
Far West Technology Dosimeters - 0.001mR-1000RFar West TechnologyDosimeters
Fluke RaySafe X2 Dosimeter Kit / X-Ray Measurement Device - Fluke Biomedical / UNFORSFluke
Fluke TNT 12000 - Elec/Xray X-Ray Radiation Dosimeter Test Tools - Fluke Biomedical - Kvp&Dose Cal-Mammo Radio - W/Al Mammo - Mo/MoFlukeTNT 12000 - Elec/Xray
Fluke TNT 12000 - Elec/Xray2 X-Ray Radiation Dosimeter Test Tools - Fluke Biomedical - Kvp&Dose-CalFlukeTNT 12000 - Elec/Xray2
Fluke TNT 12000 - Elec/Xray3 X-Ray Radiation Dosimeter Test Tools - Fluke Biomedical - Kvp&Dose-Cal-Radio-W/Al Mammo-Mo/Mo,W/Rh,W/AgFlukeTNT 12000 - Elec/Xray3
Fluke TNT 12000 - Elec/Xray4 X-Ray Radiation Dosimeter Test Tools - Fluke Biomedical - Kvp&Dose-CalFlukeTNT 12000 - Elec/Xray4
Fluke TNT 12000 - Radio Only X-Ray Radiation Dosimeter Test Tools - Fluke Biomedical - Elec Cal And Radiographic Points OnlyFlukeTNT 12000 - Radio Only
General Radio 1954 Noise DosimeterGeneral Radio
Holaday HI-3550 Magnetic Field Monitor / Dosimeter - ETS LindgrenHoladayHI-3550
Laurus RAD-60 Personal Alarming DosimeterLaurusRAD-60
Ludlum 23 Electronic Personal DosimeterLudlum23
Metrosonics DB-3080 DosimeterMetrosonicsDB-3080
Metrosonics DB-3100 DosimeterMetrosonicsDB-3100
NDS Products ND-2000C Radiography Gamma Survey Meter 0-1000mR/hr - Same as the ND-2000 With Dosimeter ChargerNDS ProductsND-2000C
Quest / SKC NoisePro DL Noise DosimeterQuestNoisePro DL
Quest DB-3080 DosimeterQuestDB-3080
Quest M-7 Noise DosimeterQuestM-7
Quest M27 Noise Dosimeter - Logging - M-27QuestM27
Quest Micro-15 Noise DosimeterQuestMicro-15
Quest Q100 Noise DosimeterQuestQ100
Quest Q220P Noise DosimeterQuest
Quest Q300 Noise DosimeterQuestQ300
Respironics JD-100 Joey Dosimeter - Healthdyne - Joey JD-100RespironicsJD-100
SGLUX UVC UV UV DosimeterSglux
Simpson 891 Noise DosimeterSimpson Electric891
Simpson 891B Noise DosimeterSimpson Electric891B
Simpson 892 Noise DosimeterSimpson Electric892
Xetex 335B Radiation Detection Instrument / Digital Dosimeter / Radiation Counter - Beta, Gamma, X-RayXeteX335B

Frequently Asked Questions

Micro Precision calibrates a radiation dosimeter by exposing it to a known, NIST-traceable radiation dose from a calibrated source and comparing the instrument’s reading to the reference value. Results are documented across the dosimeter’s measurement range, and a certificate of calibration confirming traceability to NIST is issued with every instrument returned.

Radiation dosimeters typically require calibration at least once a year, consistent with guidance in ANSI N13.5 and NRC Regulatory Guide 8.4. Micro Precision recommends setting the interval based on usage frequency, environmental exposure conditions, and the facility’s internal radiation safety program.

Dosimeter calibration is governed by ANSI N13.5 and NRC Regulatory Guide 8.4 for radiation protection instruments, performed under ISO/IEC 17025:2017 accreditation with NIST-traceable reference sources. Micro Precision’s calibration process aligns with ANSI/NCSL Z540.3 requirements for measuring and test equipment.

A dosimeter measures cumulative radiation dose received by an individual over time, while a survey meter measures the radiation dose rate present in an area at a given moment. Micro Precision calibrates both instrument types, using the appropriate NIST-traceable reference source and procedure for each.

A NIST-traceable dosimeter calibration certificate is documentation confirming the instrument’s measured response was verified against a radiation reference standard linked to national measurement standards. Micro Precision’s certificates confirm ISO/IEC 17025:2017 compliance and provide the traceability records compliance officers need for regulatory review.

Electronic personal dosimeters, direct-reading dosimeters, thermoluminescent dosimeters, and ionization chamber survey meters all require regular calibration to maintain measurement accuracy. Micro Precision calibrates a variety of these radiation dosimetry instrument types across its accredited laboratory network.

Micro Precision provides on-site dosimeter calibration for facilities that cannot remove radiation instruments from service, in addition to in-lab calibration at its ISO/IEC 17025:2017 accredited laboratories. Both options include a NIST-traceable certificate of calibration upon completion.

Privacy Preference Center