Your Reliable Blue Point Instrument Calibration Provider

Micro Precision provides NIST-traceable, ISO/IEC 17025:2017 accredited calibration and repair services for Blue Point hand tools and test instruments, including torque wrenches, multimeters, and pressure gauges. Blue Point tools serve the automotive, construction, and manufacturing industries, and our network of 50+ calibration labs keeps this equipment accurate, traceable, and audit-ready.

Blue Point is a manufacturer of hand tools known for durability and precision, with popular instrument lines that include torque wrenches, ratchets, wrenches, and cutters. Micro Precision’s accredited laboratories and experienced technicians support comprehensive calibration programs for Blue Point equipment, providing accurate calibration certificates and quality servicing that keep instruments performing to specification.

Fill out our Blue Point calibration service request form

Why Blue Point Calibration Matters

Blue Point torque wrenches and test instruments require calibration against recognized standards to maintain measurement accuracy and support compliance audits. ANSI/NCSL Z540.3 governs the calibration program requirements accredited laboratories must follow.

ANSI/NCSL Z540.3 sets the calibration program requirements for accredited laboratories performing torque wrench calibration. Micro Precision’s ISO/IEC 17025:2017 accredited labs calibrate Blue Point torque wrenches and instruments against this standard, with NIST-traceable results documented on every calibration certificate.

Importance of Blue Point Calibration and Repair

Regular calibration and repair of Blue Point equipment protects measurement accuracy, extends instrument lifespan, and supports productivity. Tools wear down with heavy use, and uncalibrated instruments produce inaccurate results that compromise quality records. Scheduled calibration and repair prevent costly replacements, keep tools operating within specification, and let technicians complete tasks efficiently and correctly the first time.

Ensure Accurate Blue Point Torque Wrench Calibration

Micro Precision calibrates Blue Point torque wrenches, including click-type, dial, and digital/electronic models such as the BPT-R, BPNMRMH, and Computorq-3 series, to maintain accurate fastening torque and support quality and safety requirements. Torque wrench calibration services confirm that these tools apply torque within specification across their working range.

Torque wrenches are Blue Point’s most widely used calibration-relevant product line, and uncalibrated torque tools directly affect fastener integrity in automotive, aerospace, and manufacturing applications. Micro Precision’s accredited laboratories test Blue Point torque wrenches against NIST-traceable reference standards and issue documented calibration certificates confirming performance to specification. Customers who also rely on Mountz torque calibration services can consolidate torque tool calibration across brands with Micro Precision.


Our Calibration Process

Micro Precision calibrates Blue Point equipment through a defined process: technicians receive and inspect each instrument, test it against NIST-traceable reference standards, adjust it if it is found out of tolerance, issue a calibration certificate, and return the instrument ready for use. This process applies to torque wrenches, multimeters, and other Blue Point instruments alike.

Micro Precision provides both in-lab calibration at accredited facilities and on-site calibration services performed at a customer’s location, giving quality teams flexibility to schedule Blue Point equipment calibration around production needs.

Blue Point Tools We Calibrate

Micro Precision calibrates a variety of Blue Point tools and instruments, with particular depth in torque wrenches given their central role in the Blue Point product line, alongside the electrical and temperature test equipment below.

  • Torque Wrenches (click-type, dial, and digital/electronic)
  • Multimeter
  • Tachometer
  • Clampmeter
  • Bimetal Thermometer
  • Thermometer
  • Pressure Gauge

Calibration Service Levels Offered

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Blue Point Calibration Services

Micro Precision’s instrument calibration services extend to Blue Point’s full test tool lineup, and customers can browse all manufacturers we calibrate to compare coverage across other torque tool and test equipment brands.

Please complete our quick Blue Point equipment calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
Blue M 0V8A OvenBlue M0V8A
Blue M 2010 Temperature ControllerBlue M2010
Blue M 31152JM100C Environmental ChamberBlue M31152JM100C
Blue M 7702HC Humidity ChamberBlue M7702HC
Blue M ABHH-16B-3 OvenBlue MABHH-16B-3
Blue M Any OvenBlue MANY
Blue M B-2730-Q OvenBlue MB-2730-Q
Blue M BM7000 Chart RecorderBlue MBM7000
Blue M BM710000000001 OvenBlue MBM710000000001
Blue M BTC4-100C Temperature ChamberBlue MBTC4-100C
Blue M C-4850-Q OvenBlue MC-4850-Q
Blue M CFR 7752C Environmental ChamberBlue MCFR 7752C
Blue M CFR7652B/CFR7652C Temp/Humidity ChamberBlue MCFR7652B/CFR7652C
Blue M CW-6680 Ultra-Temp Standard Convection OvenBlue MCW-6680
Blue M DC-2566 OvenBlue MDC-2566
Blue M DC-256C-ST350 High Temperature ChamberBlue MDC-256C-ST350
Blue M DCI-256-JY-SP OvenBlue MDCI-256-JY-SP
Blue M DTC-256C-ST30 High Temperature ChamberBlue MDTC-256C-ST30
Blue M E-555C-1 Muffle FurnaceBlue ME-555C-1
Blue M ESP-400A-9-UL OvenBlue MESP-400A-9-UL
Blue M ESP-400C-5 OvenBlue MESP-400C-5
Blue M L0-90-P Laboratory Oven - 0-260CBlue ML0-90-P
Blue M MO-1420A OvenBlue MMO-1420A
Blue M MP1406G-1 OvenBlue MMP1406G-1
Blue M MW-1120A OvenBlue MMW-1120A
Blue M OV-480A OvenBlue MOV-480A
Blue M OV-500C-2 OvenBlue MOV-500C-2
Blue M OV-520C-3 OvenBlue MOV-520C-3
Blue M OV18SA OvenBlue MOV18SA
Blue M POM-588C-3 OvenBlue MPOM-588C-3
Blue M POWERMATIC 60 OvenBlue MPOWERMATIC 60
Blue M VP100AT-1 Environmental ChamberBlue MVP100AT-1
Blue M WB-1110A OvenBlue MWB-1110A
Blue Point Act 73 Bimetal ThermometerBlue PointACT 73
Blue Point ACT 83 Thermometer - DigitalBlue PointACT 83
Blue Point ACT120A Scale - Electronic Refrigerant - 240lb / 110kgBlue PointACT120A
Blue Point CA2 ClampmeterBlue PointCA2
Blue Point DMSC683A MultimeterBlue PointDMSC683A
Blue Point EEDM501B MultimeterBlue PointEEDM501B
Blue Point EEDM503A MultimeterBlue PointEEDM503A
Blue Point EEDM503B MultimeterBlue PointEEDM503B
Blue Point EEDM504A MultimeterBlue PointEEDM504A
Blue Point EEDM504B MultimeterBlue PointEEDM504B
Blue Point EEDM586C Automotive Digital MultimeterBlue PointEEDM586C
Blue Point EEPV501A Tire Gage, Digital - 99.9PSIBlue PointEEPV501A
Blue Point GA438 Straight Edge - 18inchBlue PointGA438
BLUE POINT MT137 TACHOMETER DIGITALBlue PointMT137
Blue Point MT137A TachometerBlue PointMT137A
Blue Point MT138 Tachometer DigitalBlue PointMT138
Blue Point MT139 Tachometer DigitalBlue PointMT139
Blue Point MT139A Tachometer PhotoBlue PointMT139A
Blue Point MT145 MultimeterBlue PointMT145
Blue Point MT574C MultimeterBlue PointMT574C
Blue Point MT586A MultimeterBlue PointMT586A
Blue Point MT594A MultimeterBlue PointMT594A
Blue Point MTIND 293 ClampmeterBlue PointMTIND 293
Blue Point TEMP 1 Thermometer - DigitalBlue PointTEMP 1
Blue Point TPGD150 Pressure Gage - TireBlue PointTPGD150
Bluetec BD100MZ Feeler Gage Set - Measure Tool - Thickness Filler - 25pc Blades - 100mmBluetecBD100MZ

Frequently Asked Questions

Torque wrench calibration frequency typically follows usage intensity: high-use tools are calibrated more often, and industry practice commonly recommends calibration at least annually or immediately after a drop, overload, or noticeable change in performance. Micro Precision’s technicians calibrate Blue Point torque wrenches against NIST-traceable standards regardless of the interval a customer selects.

Blue Point torque wrench calibration cost depends on the tool model, torque range, and service level selected (Traceable, Traceable with Data, or Accredited). Micro Precision provides calibration quotes through its equipment quote request form, so customers receive pricing specific to their Blue Point torque wrench before service begins.

Micro Precision calibrates Blue Point torque wrenches through its network of 50+ ISO/IEC 17025:2017 accredited calibration labs, with both in-lab and on-site service options available. Customers submit a torque wrench calibration services request through the form on this page to begin the process.

Torque wrench calibration involves testing the tool against a certified reference standard across its working range, comparing indicated torque to actual applied torque, and adjusting the tool if it falls out of tolerance. Micro Precision’s accredited technicians perform this process for Blue Point torque wrenches and document results on a calibration certificate referencing ANSI/NCSL Z540.3 program requirements.

Micro Precision’s instrument calibration services extend to Blue Point’s full test tool lineup, and customers can browse all manufacturers we calibrate to compare coverage across other torque tool and test equipment brands.

Micro Precision’s calibration laboratories hold ISO/IEC 17025:2017 accreditation, and Blue Point torque wrenches can be calibrated at the Accredited service level, which includes the accreditation body logo and expanded measurement uncertainty on the certificate. Traceable and Traceable with Data service levels are also available for customers who do not require full accreditation.

Micro Precision calibrates Blue Point torque wrenches using reference standards with documented NIST traceability, meaning each measurement links back to national standards through an unbroken chain of comparisons. This traceability is recorded on the calibration certificate issued for every Blue Point instrument serviced.

Privacy Preference Center