Your Trusted LCR Meter Calibration Provider

Micro Precision is an ISO/IEC 17025:2017 accredited LCR meter calibration provider delivering NIST-traceable results through a global network of 50+ calibration laboratories. We calibrate a variety of LCR meter types for electronics manufacturing, aerospace, defense, R&D, and component testing organizations, issuing calibration certificates that satisfy quality audits, regulatory inspections, and compliance requirements.

Our accredited calibration process verifies all primary LCR measurement parameters: inductance (L), capacitance (C), resistance (R), impedance (Z), dissipation factor (D), quality factor (Q), and phase angle. Each parameter is tested against NIST-traceable reference standards, and as-found and as-left data is documented on the calibration certificate. Micro Precision’s ISO/IEC 17025:2017 accreditation confirms that our measurement results are traceable, verified, and backed by an accredited quality management system that meets the requirements of ISO 10012 and ANSI/NCSL Z540.3.

Fill out our LCR Meter calibration service request form

Why LCR Meter Calibration Matters

LCR meters drift over time through component aging, mechanical stress, and environmental exposure. Measurement errors in inductance, capacitance, and resistance lead to incorrect component selection, flawed circuit designs, and failed quality inspections. ANSI/NCSL Z540.3 and ISO 10012 require documented calibration at established intervals for all measuring equipment used within quality management systems.

Open/short compensation, performed by users before each test session, corrects lead and fixture effects only. It does not verify or correct the instrument’s internal measurement accuracy against NIST-traceable reference standards. Professional ISO/IEC 17025:2017 accredited calibration, performed at documented intervals, is the only method that confirms the LCR meter’s measurement parameters against national standards. Quality managers who perform routine compensation checks still require annual accredited calibration to maintain their quality program’s traceability requirements.

For industries where component measurement accuracy determines product performance, regulatory compliance, or safety, a current accredited calibration certificate provides documented assurance that every LCR measurement is traceable and reliable.


How We Calibrate Your LCR Meters

Micro Precision follows a documented calibration procedure for every LCR meter. Each instrument is received, inspected, tested against NIST-traceable reference standards across its full parameter set, adjusted as needed, and returned with a calibration certificate confirming traceability and compliance. Every step follows our ISO/IEC 17025:2017 accredited quality management system.

  • Receive and Inspect: Log the instrument details upon arrival and assess its physical condition, accessories, and test configuration before calibration begins.
  • Performance Testing: Test inductance, capacitance, resistance, impedance, dissipation factor, quality factor, and phase angle across applicable test frequencies against NIST-traceable reference standards.
  • Adjustment: Restore any out-of-tolerance measurements to within acceptable limits per manufacturer specifications.
  • Certification: Issue a calibration certificate documenting measurement results, as-found and as-left data, and a NIST traceability statement.
  • Return: Return the calibrated LCR meter with its certificate and a next-calibration-due label.


Our LCR Meter Calibration Options

Micro Precision offers in-lab and on-site LCR meter calibration to fit your operational requirements. Both options deliver ISO/IEC 17025:2017 accredited results with NIST-traceable certificates.

In-lab calibration: Ship your LCR meters to one of our 50+ accredited calibration laboratories for service under controlled conditions. Our labs accept both individual instruments and large-volume orders, with standard and rush turnaround options available.

On-site calibration: When instruments cannot be removed from your facility, our field technicians bring NIST-traceable reference standards directly to your location. On-site service minimizes operational downtime and supports continuous compliance for benchtop and rack-mounted LCR meters in production or R&D environments.

Rush service is available for time-sensitive calibration needs. Contact Micro Precision to confirm availability and lead time for your location.


LCR Meters We Calibrate

Micro Precision calibrates a variety of LCR meter types used across electronics manufacturing, component testing, R&D, and quality assurance environments. Whether you need calibration for one instrument or a fleet across multiple sites, our labs are equipped to handle major models and brands.

LCR meter types we calibrate:

  • Handheld LCR meters
  • Benchtop LCR meters
  • Precision LCR meters
  • Impedance analyzers
  • RCL meters

All types are tested across their full measurement parameter set, including inductance, capacitance, resistance, impedance, dissipation factor, and quality factor, at applicable test frequencies. Each instrument is calibrated against NIST-traceable reference standards and returned with a compliant calibration certificate.

Popular brands we calibrate:

  • Keysight
  • Agilent
  • Wayne Kerr
  • Fluke
  • Wavetek
  • Hioki
  • BK Precision
  • IET Labs

Contact us to confirm coverage for a specific model not listed above.


Calibration Service Levels Offered

Micro Precision offers three LCR meter calibration service levels to match your compliance requirements and documentation needs.

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Please complete our quick LCR Meter equipment calibration service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
Agilent 16005B LCR / Impedance MeterAgilent16005B
Agilent 16006A LCR / Impedance MeterAgilent16006A
Agilent 16043A LCR / Impedance MeterAgilent16043A
Agilent 16048B LCR / Impedance MeterAgilent16048B
Agilent 16064B LCR / Impedance MeterAgilent16064B
Agilent 16093A LCR / Impedance MeterAgilent16093A
Agilent 16093B LCR / Impedance MeterAgilent16093B
Agilent 16094A LCR / Impedance MeterAgilent16094A
Agilent 16143B LCR / Impedance MeterAgilent16143B
Agilent 16191A LCR / Impedance MeterAgilent16191A
Agilent 4192A LCR / Impedance MeterAgilent4192A
Agilent 4194AAgilent
Agilent 4195A LCR / Impedance MeterAgilent4195A
Agilent 4263A LCR / Impedance MeterAgilent4263A
Agilent 4268A LCR / Impedance MeterAgilent4268A
Agilent 4274A LCR / Impedance MeterAgilent4274A
Agilent 4276A Used LCZ MeterAgilent4276A
Agilent 4279A LCR / Impedance MeterAgilent4279A
Agilent 4284A LCR / Impedance MeterAgilent4284A
Agilent 4285A LCR / Impedance MeterAgilent4285A
Agilent 4286A LCR / Impedance MeterAgilent4286A
Agilent 4287A LCR / Impedance MeterAgilent4287A
Agilent 4288A LCR / Impedance MeterAgilent4288A
Agilent 4338B LCR / Impedance MeterAgilent4338B
Agilent 4339B LCR / Impedance MeterAgilent4339B
Agilent 4349B LCR / Impedance MeterAgilent4349B
Agilent 4396B LCR / Impedance MeterAgilent4396B
Agilent E4915A LCR / Impedance MeterAgilentE4915A
Agilent E4916A LCR / Impedance MeterAgilentE4916A
Agilent Technologies 4236B LCR Meter - 100Hz-100kHzAgilent4236B
Agilent Technologies 4248A LCR MeterAgilent4248A
Agilent Technologies 4261A LCR MeterAgilent4261A
Agilent Technologies 4262A LCR Meter - DigitalAgilent4262A
Agilent Technologies 4263B LCR Meter - 100Hz-100kHzAgilent
Agilent Technologies 4271A Digital LCR Meter - 1MHzAgilent4271A
Agilent Technologies 4271B LCR Meter - 1MHzAgilent4271B
Agilent Technologies 4275A LCR Meter - Multi Frequency - 10kHz-10MHzAgilent4275A
Agilent Technologies 4277A LCZ Meter - 10kHz-1MHzAgilent4277A
Agilent Technologies U1731A LCR Meter - HH - 20000 Count - Dual Display - 120Hz/1kHzAgilentU1731A
Agilent Technologies U1731B LCR Meter - HH - 20000 Count - Dual Display - 120Hz/1kHzAgilentU1731B
Agilent Technologies U1731C LCR Meter - HH - 20000 Count - Dual Display - 100Hz/120Hz/1KHzAgilentU1731C
Agilent Technologies U1732A LCR Meter - Handheld - 20000 Count - Dual Display - 100Hz/120Hz/1kHz/10kHzAgilentU1732A
Agilent Technologies U1732B LCR Meter - Handheld - 20000 Count - Dual Display - 100Hz/120Hz/1kHz/10kHzAgilentU1732B
Agilent Technologies U1732C LCR Meter - Handheld - 20000 Count - Dual Display - 100Hz/120Hz/1kHz/10kHzAgilentU1732C
American Reliance 470D LCR MeterAmerican Reliance (AMREL)470D
Amprobe LCR554 LCR MeterAmprobeLCR554
Amprobe LCR55A LCR Meter Hand HeldAmprobeLCR55A
Analog Equipment S-SB LCR Meter / Smart TweezersAnalog EquipmentS-SB
B&K PRECISION 879B LCR MeterBk Precision
B&K PRECISION 886 Synthesized In-Circuit LCR/ESR Meter with 100kHz Test FrequencyBk Precision886
B&K Precision 8.78112E+15 LCR MeterBk Precision8.78112E+15
B&K Precision 878 LCR Meter - 4 Digit HH 10 mF 10 Mega.Ohms 10000 HBk Precision878
B&K Precision 8781117508100098 LCR METER - 08781117508100098Bk Precision8.78112E+15
B&K Precision 889B LCR Meter / ESR Meter - Bench - 600V AC/DC - Current 2000mABk Precision889B
B&K Precision 895 LCR Meter - Bench - 20Hz-1MHzBk Precision895
BECKMAN LM22A LCR Meter / Component TesterBeckmanLM22A
Biddle 270183 LCR MeterBiddle270183
Biddle B183 LCR MeterBiddleB183
Boonton 5110 LCR MeterBoonton5110
Boonton 71A Inductance MeterBoonton71A
Cambridge 520 LCR METERCambridge520
Chroma 11021Chroma
Circuit Specialists MY6243 LCR MeterCircuit SpecialistsMY6243
ESI 254 Impedance Meter / LCR MeterEsi254
Eucol U2817 Precision LCR Meter - 50Hz-100kHzEucolU2817
Excelta ST-1 LCR Meter / Smart TweezersExceltaST-1
Excelta TM-150 LCR Meter / Smart Tweezers / Tweezer Meter / R-C-L / IntelliTweezeExceltaTM-150
Excelta TM-200 LCR Meter / Smart Tweezers / Tweezer Meter / R-C-L / IntelliTweezeExceltaTM-200
Excelta TM-500 LCR Meter / Smart Tweezers / Tweezer Meter / R-C-L / IntelliTweezeExceltaTM-500
Extech 380153 LCR MeterExtech380153
Extech 380193 Passive Component LCR MeterExtech380193
Extech 381820 LCR MeterExtech381820
Fluke PM6302 LCR Meter - PhilipsFlukePM6302
Fluke PM6303A Automatic RCL Meter - PhilipsFlukePM6303A
Fluke PM6304 Automatic RCL Meter - PhilipsFlukePM6304
Fluke PM6306 RCL Meter / LCR MeterFlukePM6306
General Radio 1630AV Inductance BridgeGeneral Radio
General Radio 1632A Inductance Bridge - 1632-AGeneral Radio
General Radio 1633A Inductance BridgeGeneral Radio
General Radio 1650A Inductance BridgeGeneral Radio
General Radio 1650B Inductance Bridge - 1650-BGeneral Radio
General Radio 1657 LCR Bridge / RLC DigiBridge - QuadTechGeneral Radio1657
General Radio 1687B LC BridgeGeneral Radio
General Radio 1689M Digibridge / Bridge - LCRGeneral Radio1689M
Global LCR220 Impedance MeterGlobalLCR220
Global Specialties LCR-600 High Precision LCR Meter - 100 kHzGLOBAL SPECIALTIESLCR-600
GW Instek LCR-821GW Instek
Hioki 3532-50 LCR Meter / HiTesterHioki
Hioki 3540Hioki
Hioki IM3523Hioki
Hioki IM3532 LCR MeterHiokiIM3532
Hioki IM3536 LCR MeterHiokiIM3536
Ideal ST5 LCR Meter / Smart TweezersIdealST5
Iet Labs 1688 Lc DigibridgeIET Labs1688
IET Labs LCR-620 LCR MeterIET Labs
Instek  LCR-916 LCR Meter - GW InstekInstek
Instek LCR-6002 Precision LCR MeterInstekLCR-6002
Instek LCR-6100 Compact LCR Meter - 10 Hz to 100 kHzInstekLCR-6100
Instek LCR-6300 LCR Meter - Bench - 300kHzInstekLCR-6300
Instek LCR-8101-G Precision LCR Meter - GWInstekLCR-8101-G

FAQs

LCR meters require calibration at minimum once per year. Instruments in daily laboratory use, high-humidity environments, or critical component testing applications may require calibration every six months. Any LCR meter that has been dropped, impacted, repaired, or is producing inconsistent readings must be recalibrated before returning to service, regardless of the last calibration date.

LCR meter calibration verifies and adjusts performance across all primary measurement parameters: inductance (L), capacitance (C), resistance (R), impedance (Z), dissipation factor (D), quality factor (Q), and phase angle. Each parameter is tested at applicable test frequencies against NIST-traceable reference standards, and as-found and as-left data is recorded. Results are documented in a calibration certificate confirming traceability and compliance.

An LCR meter measures the inductance, capacitance, and resistance of electronic components. It is used in electronics manufacturing to verify component specifications, in R&D for circuit design and validation, and in quality assurance programs to identify out-of-specification components. Industries including aerospace, defense, telecommunications, and medical device manufacturing rely on LCR meters for component-level electrical testing.

A compliant LCR meter calibration certificate includes the instrument model and serial number, calibration date and next-due date, test method, as-found and as-left measurement data for each parameter, pass/fail status, NIST traceability statement, measurement uncertainty, and the calibrating laboratory’s ISO/IEC 17025:2017 accreditation body name and scope reference. Micro Precision provides this documentation with every calibration service.

LCR meter calibration pricing depends on instrument type, measurement parameters included, number of test frequencies, and selected service level. Precision and benchtop LCR meters are generally more expensive to calibrate than basic handheld models due to additional measurement parameters and test frequency coverage. Contact Micro Precision for a quote based on your instrument inventory and required service level.

LCR meter calibration in accredited laboratories is governed by ISO/IEC 17025:2017, which sets requirements for calibration laboratory competence. ANSI/NCSL Z540.1 and ANSI/NCSL Z540.3 define calibration requirements for measuring and test equipment. ISO 10012 covers measurement management systems. NIST traceability ensures measurement results are referenced to national standards.

An LCR meter measures inductance, capacitance, and resistance at one or a few test frequencies, covering most component testing and quality assurance applications. An impedance analyzer measures complex impedance across a broad sweep of frequencies and is used in R&D and precision testing applications requiring detailed component characterization. Both instrument types require periodic ISO/IEC 17025:2017 accredited calibration to maintain measurement accuracy and traceability.