Your Trusted Hardness Tester Calibration Provider

Micro Precision is an ISO/IEC 17025:2017 accredited calibration provider delivering NIST-traceable hardness tester calibration services through a network of more than 50 labs. Quality managers, metrologists, and procurement teams across aerospace, defense, medical device, automotive, and manufacturing and metallurgy industries rely on Micro Precision to keep Rockwell, Brinell, Vickers, and Leeb hardness testers within their required verification standards. Every calibration follows ASTM E18 verification requirements for Rockwell hardness testers, with parallel technical rigor applied to Brinell, Vickers, and Leeb instruments. Micro Precision’s technicians work across a variety of hardness tester models and configurations, from bench-top production testers to portable field units, giving procurement officers a single certified vendor for an entire hardness testing fleet rather than a patchwork of regional providers.

Micro Precision’s ISO/IEC 17025:2017 accreditation and NIST-traceable measurement chain give quality managers a documented, audit-ready calibration record for every Rockwell, Brinell, Vickers, or Leeb hardness tester submitted, supporting compliance across aerospace, defense, medical, automotive, and manufacturing and metallurgy quality systems.

Fill out our Hardness Tester calibration service request form

Why Hardness Tester Calibration Matters

Hardness tester calibration matters because an uncalibrated instrument produces measurement error that can mask material defects, leading to failed parts, safety incidents, and non-conformance findings in audits. ANSI/NCSL Z540.3 establishes the calibration program requirements that quality systems depend on. Without a documented, accredited calibration program, a hardness reading cannot be trusted to represent the actual mechanical properties of the material tested.

Quality managers need a documented, traceable calibration history to pass ISO/IEC 17025:2017 and customer audits without corrective action findings. Procurement officers need a certified vendor whose calibration certificates hold up under scrutiny from aerospace, defense, medical, automotive, and manufacturing customers. Lab technicians and metrologists need confidence that test block readings reflect true hardness values, not drift in the load cell, indenter, or measurement system. Micro Precision’s calibration program addresses each of these concerns directly, applying ANSI/NCSL Z540.3 program discipline to every Rockwell, Brinell, Vickers, and Leeb hardness tester it services.

Ensure Accurate Hardness Tester Calibration

Ensuring accurate hardness tester calibration means verifying the instrument’s indenter, load application, and measurement system against certified test blocks traceable to NIST, then documenting the results on a certificate of calibration. Micro Precision follows a defined sequence for every hardness tester received: inspect the instrument, apply certified test blocks across the applicable hardness scale, measure and record results, adjust the instrument where needed, and issue documentation confirming the outcome. Every hardness tester returns with a certificate of calibration documenting the verification performed and the standards referenced. Micro Precision offers standard turnaround alongside faster turnaround options for hardness testers on a tight production or audit schedule, without compromising the verification steps required to maintain accredited calibration.

Micro Precision calibrates hardness testers by inspecting the instrument, applying NIST-traceable certified test blocks across the applicable Rockwell, Brinell, Vickers, or Leeb scale, measuring and recording as-found and as-left results, making adjustments where required, and issuing a certificate of calibration for every instrument.


Our Calibration Options

Micro Precision offers hardness tester calibration through both in-lab and on-site service, giving quality managers and procurement officers a choice based on equipment size, production schedule, and downtime tolerance. In-lab calibration ships the instrument to one of Micro Precision’s ISO/IEC 17025:2017 accredited labs for full calibration under controlled conditions. On-site calibration brings a Micro Precision technician directly to the facility.

On-site service is especially valuable for large or fixed-installation hardness testing systems that are impractical to ship, as well as for facilities managing a variety of hardness testers across multiple production lines. Bringing calibration to the equipment minimizes downtime and keeps testing systems in production longer between service visits.

Both in-lab and on-site hardness tester calibration are backed by NIST traceability and documented on a certificate of calibration referencing applicable industry standards. Micro Precision provides standard turnaround for both service types, with faster turnaround options available for time-sensitive audit or production needs across its network of more than 50 calibration labs.

Hardness Tester Types We Calibrate

Micro Precision calibrates a variety of hardness testing instruments across Rockwell, Brinell, Vickers, and Leeb testing methods, supporting bench-top, portable, and microhardness configurations used in production and quality labs.

Hardness tester models not listed here are likely supported as well. Contact Micro Precision to confirm calibration availability for a specific make and model. Hardness tester calibration is available as part of Micro Precision’s broader Mechanical & Dimensional Calibration capabilities.

Calibration Service Levels Offered

Micro Precision offers hardness tester calibration at multiple service levels, from basic traceable certification to fully accredited documentation, so quality programs can match the level of rigor their industry requires.

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Hardness Tester Calibration Services

Micro Precision delivers ISO/IEC 17025:2017 accredited, NIST-traceable hardness tester calibration services for Rockwell, Brinell, Vickers, and Leeb hardness testers, backed by a network of more than 50 calibration labs. Quality managers get audit-ready documentation. Procurement officers get a single certified vendor for an entire hardness testing fleet. Lab technicians get calibration results they can trust. Request a calibration quote today and put a definitive standard behind your hardness testing program.

Please complete our quick Hardness Tester calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
Dietert 473 Green Hardness Tester - B ScaleDietert
Digicon TH-200 Shore A Hardness TesterDigicon
DMQ QH5 Hardness TesterDMQQH5
ED&D BPT-01 Ball Pressure TesterED&DBPT-01
Elcometer F108-1C 108 Hydraulic Adhesion Tester / Analogue Dial Type / 0-3500 PSIElcometerF108-1C
Elcometer F108-2C 108 Digital Hydraulic Adhesion Tester / 0-3500 PSIElcometerF108-2C
Fowler 53-760-007 Portable Hardness TesterFowler53-760-007
G&R HT 1000A LEEB Hardness Tester - PortableG&RHT 1000A
GE Inspection Technologies DynaPOCKET Hardness TesterGE Sensing & Inspection TechnologiesDynaPOCKET
GE MIC 10 Hardness Tester - GE KrautkramerGEMIC 10
Gould 21-9010-01 Roughness Standard / Roughness Speciment - 1 PatchGould21-9010-01
Leco DM-40/M400 Micro Hardness Tester - Knoop 700HK rangeLECODM-40/M400
Leco LM300AT Microindentation Hardness TesterLECOLM300AT
Leco M-400-H1 Hardness Tester MicroLECOM-400-H1
Louis Small H9-6 Hardness TesterLouis Small
Mitutoyo 810-200A Hardness Tester Rockwell 120V AC Preliminary test force 98.07N (10kgf) Test force 588.4N (60kgf) 980.7N (100kgf) 1471N (150kgf) Minimum reading 0.5 Test force setting By weight exchange Load control Automatic (loading duration unloading) Anvil Flat (Mitutoyo810-200A
Mitutoyo 810-218A Hardness Tester - Total Test Force 588.4N (60kgf) 980.7N (100kgf) 1471N (60-100-150kgf) - Preliminary test force N 98.07 kgf 10 - Model ARK-600Mitutoyo810-218A
Mitutoyo 810-263A Hardness Tester - Portable - 120V AC Measuring range Vickers 32HV - 999HV Brinell 81HB - 767HB for hard specimen (steel) 42HB - 169HB for soft specimen (brass) Rockwell B 41.0HRB - 110.0HRB for hard specimen (steel) 10.0HRB - 93.5HRB for soft specimeMitutoyo810-263A
Mitutoyo 810-278 Impact Type Hardness Tester - Hardness value L hardness (conforming to ASTM A 956) Functions - Hardness value conversion: Rockwell C (20.0HRC - 68.0HRC) Rockwell B (13.5HRB - 99.5HRB) Vickers (80HV - 940HV) Shore (30.1HS - 647HS)Mitutoyo810-278
Mitutoyo ARK-600 Hardness Tester - Total Test Force 588.4N (60kgf) 980.7N (100kgf) 1471N (60-100-150kgf) - Preliminary Test Force N 98.07 kgf 10 - Order# 810-218MitutoyoARK-600
Mitutoyo HH-110 Hardmatic Analog Tester - Order# 810-502MitutoyoHH-110
Mitutoyo HH-120 Hardness Tester - Portable - 120V ACMitutoyoHH-120
Mitutoyo HH-401 Impact Type Hardness Tester - Hardness value L hardness (conformingto ASTM A 956) Functions - Hardness value conversion: Rockwell C (20.0HRC - 68.0HRC) Rockwell B (13.5HRB - 99.5HRB) Vickers (80HV - 940HV) Shore (30.1HS - 647HS)MitutoyoHH-401
Newage JR Hardness TesterNewageJR
Pharma Test PTB-311E Tablet Hardness TesterPharma TestPTB-311E
Pharmatron Multitest 50 Tablet Hardness Tester: 0 to 50KPPharmatronMultitest 50
Phase II PHT-950 Digital Hardness TesterPhase IIPHT-950
Phase II+ MET-U1A Ultrasonic Portable Hardness Tester - Phase 2 PlusPhase IIMET-U1A
Precise EPX-5500 Portable Hardness TesterPreciseEPX-5500
PTC Instruments 316 Portable Steel Hardness TesterPTC Instruments316
Rockwell 900-331 Hardness TesterRockwell900-331
Rockwell AR-10 Hardness Tester - Rockwell 120V AC Preliminary test force 98.07N (10kgf) Test force 588.4N (60kgf) 980.7N (100kgf) 1471N (150kgf) Minimum reading 0.5 Test force setting By weight exchange Load control Automatic (loading duration unloading) Anvil FlatRockwellAR-10
Rockwell HR-150A Hardness Tester - B & C / DonghuaRockwellHR-150A
Rockwell Phase II 900-385 Hardness TesterRockwellPhase II 900-385
Shimadzu 7955 Hardness Tester - (HRC, HRB, Vickers, Brinell)Shimadzu7955
Starrett 3811A Compact Hardness TesterStarrett3811A
Starrett 3814 Hardness Testers Bench Analog - 67754Starrett3814
Starrett 3815 Twin Analog Hardness TesterStarrett3815
Starrett 3816 Hardness Testers Bench Analog - 67754 / Nos. 3814, 3816, 3817Starrett3816
Starrett 3817 Hardness Testers Bench Analog - 67754 / Nos. 3814, 3816, 3817Starrett3817
Taylor Hobson Surtronic Duo Profilometer / Surface Tester - 112-2916 (2 parameter model) and 112-3115 (5 parameter model) - Replaced by the Surtronic Duo-9Taylor Hobson
Vanderkamp Vankel Varian VK200 Tablet Hardness TesterVanderkamp Vankel VarianVK200
Wallace H12 Hardness Tester - Micro RubberWallaceH12
Webster B Hardness TesterWebsterB
Wilson Rockwell 3 JR Hardness TesterWilson Rockwell3 JR
Wilson Rockwell 3JR Hardness TesterWilson Rockwell3JR

Frequently Asked Questions

Hardness testers are typically calibrated on an industry-common interval, most often annually, adjusted for usage intensity, equipment type, and the quality system’s internal requirements. High-volume production testers and instruments supporting aerospace, defense, or medical quality programs often require more frequent verification between full calibrations.

Micro Precision calibrates hardness testers under its ISO/IEC 17025:2017 laboratory accreditation, applying ANSI/NCSL Z540.3 calibration program requirements across Rockwell, Brinell, Vickers, and Leeb instruments. Every calibration is backed by NIST traceability and documented on a certificate of calibration referencing the accreditation and program standards applied.

Hardness tester calibration matters because an uncalibrated instrument can produce readings that mask real material defects, leading to failed parts, safety incidents, or non-conformance findings during an audit. Quality managers rely on documented, NIST-traceable calibration records to pass ISO/IEC 17025:2017 and customer audits without corrective action findings.

Calibrating a hardness tester involves inspecting the instrument, applying NIST-traceable certified test blocks across the applicable hardness scale, measuring and recording results, making adjustments where needed, and issuing a certificate of calibration. Micro Precision performs this process for Rockwell, Brinell, Vickers, and Leeb hardness testers.

Hardness testers are calibrated using certified test blocks manufactured and traceable to NIST for the specific hardness scale and testing method involved, such as Rockwell, Brinell, or Vickers. Micro Precision uses NIST-traceable test blocks appropriate to each hardness tester’s applicable scale during every calibration performed.

Micro Precision calibrates hardness testers on-site as an alternative to shipping the instrument to a lab, sending a technician directly to the facility. On-site service is especially useful for large, fixed-installation, or hard-to-move hardness testing systems, and it is available across Micro Precision’s network of more than 50 calibration labs nationally.

Calibrated measurement equipment is a core requirement of both ISO 9001 quality management systems and ISO/IEC 17025:2017 laboratory accreditation. Hardness testers used to make product acceptance or quality decisions must be calibrated on a documented schedule with traceable certificates to satisfy auditors under either standard.

Privacy Preference Center