Your Trusted Source Meter Calibration Provider

Micro Precision is an ISO/IEC 17025:2017 accredited calibration provider with NIST-traceable reference standards and a network of more than 50 laboratories operating worldwide. Source meters, also called source measure units (SMUs), combine sourcing and measurement functions in one instrument, and even small measurement drift undermines the accuracy of every downstream test result built on those readings.

Micro Precision provides ISO/IEC 17025:2017 accredited source meter and SMU calibration with NIST-traceable standards, supporting aerospace, defense, medical device manufacturing, automotive, and general manufacturing industries. Our global network of more than 50 laboratories delivers consistent, documented calibration results accepted by quality auditors and regulatory bodies across regulated industries worldwide.

Source meter and SMU calibration is one part of Micro Precision’s broader electrical calibration services portfolio. Micro Precision already services specific instruments including the Keithley 2450 and Keithley 2612B, part of our dedicated Keithley instrument calibration services.

Fill out our Source Meter calibration service request form

Why Source Meter Calibration Matters

Source meter calibration matters because sourcing and measurement accuracy directly affects R&D data integrity, production test yield decisions, and regulatory compliance. A source meter or SMU that drifts out of tolerance produces readings that appear valid but mask device characterization errors, mislead pass/fail testing decisions, and create non-conformance findings during ISO/IEC 17025:2017-based quality audits.

Regulatory frameworks reinforce this requirement directly. ANSI/NCSL Z540.3 requires documented, objective evidence of calibration for measuring and test equipment used in regulated processes, while ISO 10012 establishes measurement management system requirements, including calibration intervals and traceability controls. For quality managers and compliance officers, a valid calibration certificate with clear traceability is not optional.

Procurement officers rely on accredited calibration vendors to reduce sourcing risk and simplify audit preparation, while lab technicians and test engineers depend on accurate source and measurement readings to trust their characterization and production test results. Micro Precision supports both priorities with standard and rush turnaround options and both in-lab and on-site calibration service, backed by ISO/IEC 17025:2017 accreditation.

Ensure Accurate Source Meter Calibration

Accurate source meter calibration requires a structured process that verifies both sourcing and measurement functions against known references and corrects any deviation found. Micro Precision follows a documented calibration workflow for every source meter and SMU received, performed under the controls required by our ISO/IEC 17025:2017 accreditation.

The process for each instrument includes:

  1. Receipt and inspection — instrument condition, channel count, and source/measure range configuration are verified on arrival
  2. Performance testing — the source meter is tested against laboratory reference standards traceable to NIST across its sourcing and measurement functions to establish as-found status
  3. Adjustment — systematic measurement errors are corrected using calibration methods appropriate to the instrument’s type and range configuration
  4. Post-adjustment verification — measurements confirm the instrument performs within required parameters after calibration
  5. Documentation — a certificate of calibration is issued, documenting the calibration date, interval, standards used, and as-found and as-left data
  6. Return — the calibrated source meter is packaged and returned with its certificate of calibration

Standard and rush turnaround options are available for time-critical programs. Contact our team to discuss current lead times and priority scheduling.


Our Calibration Options

Micro Precision offers both in-lab and on-site source meter calibration to match your equipment configuration, testing environment, and program timeline. Choosing between the two options depends primarily on whether the source meter is a benchtop R&D instrument or a unit integrated into an automated test system.

In-Lab Calibration
Ship your source meter to one of our accredited laboratories for full-capability calibration under controlled conditions. In-lab service supports the complete range of calibration documentation options, including ISO/IEC 17025:2017 accredited certificates with NIST-traceable measurement results.

On-Site Calibration
For source meters and SMUs integrated into automated test systems or production racks that cannot be removed from service, Micro Precision sends qualified calibration technicians directly to your facility. On-site calibration reduces downtime, eliminates shipping risk, and keeps production and test operations running while delivering the same documentation options available for in-lab service.

Rush Turnaround
Standard and rush turnaround options are available for both in-lab and on-site service. Contact our team to discuss current lead times and priority scheduling.

Source Meter Types We Calibrate

Micro Precision calibrates a variety of source meter and source measure unit (SMU) types used across research, characterization, and production test environments.

  • Single-channel source measure units used in device characterization and R&D test
  • Multi-channel source measure units used in automated production test systems
  • Source meters used in semiconductor and component characterization
  • Source meters integrated into ATE (automated test equipment) racks
  • General-purpose SMUs used in university and industrial research labs
  • Benchtop source meters used for IV curve tracing and parametric testing

If your source meter or SMU model is not listed here, contact our team to confirm support.

Calibration Service Levels Offered

Micro Precision offers service levels to match your quality program requirements, from NIST-traceable certificates to fully accredited calibration documentation with measurement uncertainty statements.

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Source Meter Calibration Services

Micro Precision delivers ISO/IEC 17025:2017 accredited source meter and SMU calibration with NIST traceability, documented certificates, and on-site service options for automated test system integration. With more than 50 laboratories serving aerospace, defense, medical, automotive, and manufacturing industries, Micro Precision provides the accredited calibration record your quality program requires. Submit a request today to discuss your source meter inventory, service level requirements, and turnaround options.

Please complete our quick Source Meter calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
Keithley 236 Source Measure UnitKeithley236
Keithley 2400 Source Meter 200V and 1A 20W Power OutputKeithley2400
Keithley 2400-C Source MeterKeithley2400-C
Keithley 2401 Source MeterKeithley2401
Keithley 2410 SourceMeterKeithley2410
Keithley 2420 3A Source MeterKeithley2420 3A
Keithley 2420 SourceMeterKeithley2420
Keithley 2425 Digital SourceMeter 20WKeithley2425
Keithley 2430 Source MeterKeithley2430
Keithley 2430-C Source Meter, 1kW PulseKeithley2430-C
Keithley 2450 Source MeterKeithley2450
Keithley 251074-002 TEC Source MeterKeithley251074-002
Keithley 2601B Source Meter - SMU instrument, 1ChannelKeithley
Keithley 2602 Dual Channel Source MeterKeithley
Keithley 2602B System Source MeterKeithley
Keithley 2611 Source MeterKeithley2611
Keithley 2612 Dual-Channel System Source Meter 200vKeithley2612
Keithley 2612A System Source MeterKeithley2612A
Keithley 2614B Source Meter - 2‑Channel SystemKeithley2614B
Keithley 2635A Dual Source Meter fAKeithley2635A
Keithley 2636B Source Meter SMU Instrument, 2-ChannelKeithley2636B
Keithley 2651A Source Meter - 50A 40vKeithley2651A
Keithley 2657A Source Meter - 180W / 3000V / 0.02AKeithley2657A
The Keithley 2602A Source Meter / SourceMeterKeithley2602A

Frequently Asked Questions

A source measure unit (SMU) is a test instrument that combines a precision power supply, a digital multimeter, and an electronic load in one device, allowing it to source and measure voltage or current simultaneously. Source meters and SMUs are used together across R&D, production test, and semiconductor characterization applications.

Yes. “Source meter” and “source measure unit” describe the same instrument category and are used interchangeably across the industry, including by Keithley, the manufacturer most associated with the SourceMeter product line. Micro Precision calibrates source meters and SMUs under one accredited scope regardless of which term is used.

Micro Precision recommends an annual calibration interval for most source meters and SMUs, consistent with common quality program requirements and ANSI/NCSL Z540.3 guidance for measuring and test equipment. Instruments used in high-precision production test or characterization work may warrant a shorter interval based on usage and risk.

NIST traceability confirms a source meter’s measurement results connect through an unbroken chain to national standards held by the National Institute of Standards and Technology. ISO/IEC 17025:2017 accreditation goes further, adding independent, third-party verification that the calibrating laboratory’s processes, equipment, and personnel reliably produce those traceable results. Many quality programs specifically require accredited documentation.

Source meter and SMU calibration cost depends on the instrument model, number of source and measure ranges, and service level selected. Micro Precision does not publish flat-rate pricing because scope varies by manufacturer and configuration. Contact our team for a calibration quote specific to your source meter inventory.

Every Micro Precision source meter calibration includes a certificate of calibration documenting the calibration date, defined interval, reference standards used, and as-found and as-left measurement data. The certificate confirms NIST traceability and, where applicable, ISO/IEC 17025:2017 accreditation scope, giving quality managers the audit trail their compliance programs require.

Yes. Micro Precision provides on-site calibration for Keithley source meters and other SMUs integrated into automated test systems where shipping is impractical. Qualified technicians travel to your facility with NIST-traceable reference standards and complete the same documented calibration process used in our accredited laboratories, including certificate issuance.

Privacy Preference Center